viflow logoknowledge base

Contact Us

Menu
en de
  • viflow product page
  • Support request

Contact Us

  • viflow knowledge base
  • viflow – help
  • Program Interface
  • The viflow Menue Ribbon
  • "Data" tab
The viflow Menue Ribbon

"Data" tab

Applies to: viflow (subscription | 9 | 8) | Article: 1561069 | Updated on 26.04.2024

All functions relating to the import from various sources into the process model are summarized in the Data tab. In addition, the paths of the hyperlinks or additional texts can be changed here, for example.

"Import" group

You can use this function to import processes from other viflow process models (file or database), from Visio files or from other sources (eg Excel, text files).

A detailed functional description of the import functions can be found in the chapters:

››› Import from viflow process model

››› Import from Visio file

››› Import from other sources

"Translations" group

In this group you can export the content in Excel format and import it again after translating it into another language.

A detailed functional description of this import/export function can be found in the chapters:

››› Perform export for translation

››› Perform import for translation

Change Group

Hyperlinks

If you have used hyperlinks in the viflow information and want to change the location of the linked documents, use this function:

  1. Click the Hyperlinks button.The Replace tab in the Search window opens, the Type is set to Information and the Property to Hyperlink by default.
  2. Enter the previous path or parts of it in the Find field and click on [ENTER] .The search results are displayed in the right part of the window and in the Hits field you can see the text passages found.
  3. Enter the new path to the documents in the Replace field.Highlight the object whose hyperlink is to be changed and click the Replace button. The text is replaced and the next line is highlighted.
    If you want to change all entries displayed in the list, click the All button.
    Example: Your linked documents were originally stored under "P:\Documents" and are to be stored on a different drive under "H:\QM\Documents" in the future.
    This way, you don't have to manually change all the links of each document in the Hyperlink field in the information's properties window.
  4. Close the window by clicking the [X] icon.
Delete

You can find more information on finding and replacing text in the chapter ››› Find and replace text

Information Prefix

If you have used prefixes in the viflow information, these can be changed centrally:

  1. Click the Information Prefix button.
    The Replace tab in the Search window opens, the Type is set to Information and the Property to Prefix by default.
  2. Enter the search term or parts of it in the Find field and click on [ENTER].
    The search results are displayed in the right part of the window and in the Hits field you can see the text passages found.
  3. Enter the new prefix for the information in the Replace field.
    Highlight the object whose prefix is to be changed and click the Replace button. The text is replaced (Column Hit) and the next line is marked.
    If you want to change all entries displayed in the list, click the All button.
  4. Close the window by clicking the [X] icon.
Delete

The procedure for replacing information prefixes corresponds to that described under hyperlinks (see above).

You can find more information on finding and replacing text in the chapter ››› Find and replace text

"Check" group

Spelling

viflow has an integrated spell checker that underlines incorrect text in the individual fields in red.

However, you can also perform a check of all content or content filtered by type and property:

  1. Click the Spelling button.
    The Spell Check window opens, and all the content of the process model is displayed on the right.
    Filter the content by entering the type (e.g. Processes) and property (e.g. Name) and click on Search.
  2. If you click on the individual entries in the Match field, the erroneous text will be underlined in red.Correct the errors directly in the Hits column or call up the properties of the respective object.
  3. Close the window by clicking the [X] icon.
Delete

The procedure for checking spelling largely corresponds to that described under hyperlinks (see above).

You can find more information on finding and replacing texts in the chapter ››› Find and replace text

Links

Hyperlinks that are not (or no longer) working in the entire process model are displayed when you click Links in the Check group.

Delete

Only hyperlinks entered in the properties window of the information in the Hyperlink field are taken into account. Incorrect hyperlinks assigned to graphics or Visio elements are not taken into account.

With the Check Web Resources and Show unknown Link Types options, you can specify whether Internet links should also be checked and unresolvable links should be displayed.

If you double-click an entry in the list, the properties of the object are opened. Here you can then correct the incorrect hyperlink .

Local Data group

Remove

With a click on Remove you can - if available - delete all local properties of an object marked in the graphic.

Delete

Danger!

The action cannot be undone.


All articles in The viflow Menue Ribbon

  • Quick Access Toolbar
  • Overview
  • "Data" tab
  • "Reports" tab
  • "Graphic" tab
  • "Insert" tab
  • "Design" tab
  • "Developer" tab
  • "Main Version" tab
  • "Version conflicts" / "Graphic conflicts" tab
  • "View" tab
Quicklinks
  • viflow international
  • viflow functions
  • Trainings
  • viflow life cycle
  • viflow system requirements
  • Remote support
  • viflow updates
SUBMIT SUPPORT REQUEST

Couldn't find a solution? Make a support request.

Submit a support request


FOLLOW US

We inform you regularly about current developments, trends and news around viflow. Just choose the format that's right for you.

Newsletter subscription
vilfow auf facebook ViCon auf Xing ViCon auf Linkedin vilfow auf youtube
Contact Central office

+49 511 696048-0

Sales

+49 511 696048-20

Support support@viflow.de
  • Contact
  • T&Cs
  • Conditions of Use
  • Privacy Statement
  • Legal Info

Copyright © 2003 – 2025 ViCon GmbH | viflow knowledge base | All rights reserved.

info@vicon.biz +49 511 696048-0
Knowledge Base Software powered by Helpjuice

Definition by Author

0
0
  • Kontakt
  • AGB
  • Nutzungsbedingungen
  • Datenschutz
  • Impressum

Copyright © 2003 – 2021 ViCon GmbH | Funktionen | Alle Rechte vorbehalten.

info@vicon.biz +49 511 696048-0
Expand